Teledex Y Series User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
Y SERIES EXP212, EXP224, AND EXP248 USER GUIDE www.teledex.com 25
Also keep each EXP212, EXP224, and EXP248
system site free of dust and other pollutant that
could affect system performance. In addition,
be sure to maintain the environment conditions
at the central office and at each remote system
site. The ideal operating temperature is about
20°C. The following is the acceptable operating
condition range:
• –10°Cto65°Cand0%to95%humidityat35°C
2.2 Powering the EXP212,
EXP224, or EXP248 Up or Down
This section describes how to power up and
power down the DSLAM.
Table 2.2 Procedures of Powering Up the
DSLAM
Step Action
1 Put on the anti-static wrist strap and
connect it to a grounding point.
2 Ensure that the DSLAM is securely
installed.
3 Ensure that the DSLAM ground strap is
connected to a suitable ground point.
4 Ensure that –48 Vdc power is being
supplied to the DSLAM. For EXP212 and
EXP224: If you use AC power, ensure the
AC power is being supplied.
5 Ensure that the fan card is installed
(EXP248 only).
6 Ensure that the POTS lines, subscriber
lines, and alarm equipment are
connected.
7 Slide the power switch on the faceplate
to ON (EXP248 only).
8 Wait for a minute, and then check the
LEDs on the DSLAM. If the LEDs show
some problem, refer to section 3.2 for
information on how to resolve problems
indicated through LEDs.
Table 2.3 Procedures of Powering Down the
DSLAM
Step Action
Caution: Powering down the DSLAM stops DSL
service to subscribers. POTS service is not
affected.
1 Put on the anti-static wrist strap and
connect it to a grounding point.
2 Slide the power switch on the faceplate
to Off (EXP248 only).
3 Disconnect the AC power cord from
the AC supply socket on the front panel
(EXP212 and EXP224).
2.3 Controls and LED Indication
The EXP212, EXP224, and EXP248 have simple
controls and indicators on its front panel.
The indicators show the current operating
states of various system elements and serve
as maintenance aids for local technicians at
each site. The remaining controls on the cards
are also provided for local system testing and
maintenance.
Table 2.4 EXP224 and EXP248 Controls and LED
Indication
EXP224 Front Panel
EXP248 Front Panel
LED Color
Indication/
Condition
SYS Yellow At power on
phase
Red Self-test fail
Green Normal
operation
Page view 24