Y SERIES EXP212, EXP224, AND EXP248 USER GUIDE www.teledex.com 11
–36V DC (EXP212, EXP224), –72V through –38V
DC (EXP248), and make sure that the polarity is
correct.
Warning—Ensure that all power sources to the
chassis (power distribution panel) are turned off
during the connection.
Note—It is recommended that the –48V DC
power be supplied directly and independently
by a power feeding system. Also, avoid having a
parallel or mutual connection with other –48VDC
power supplies of telecommunication equipment.
This is to guard against interference when other
equipment is on.
AC POWER CONNECTION (OPTION)
If your EXP212, EXP224, and EXP248 uses
AC power, connect the AC power cord to the
AC supply socket on the front panel (EXP212,
EXP224) or rear panel (EXP248) of the DSLAM
(refer to Figure 1.5), and plug the cord into the
external power source. The voltage must be 100
to 240 V AC.
GROUND CONNECTIONS
This section provides the grounding rule for the
EXP212, EXP224, and EXP248. All remote system
sites must be properly grounded for optimum
system performance.
In Central Office
There should be a CO GND that is adequately
grounded. If the measured resistance from the
grounding screw (on the rear panel of the DSLAM,
refer to Figure 1.5) to CO GND is less than 5 Ohm,
then it can be assumed that the system is well
grounded. If the measured resistance is larger
than 5 Ohm, it is recommended to connect the
grounding screw to CO GND using #14 or #12
AWG wire gauge conductor.
In Remote Cabinet
The EXP212, EXP224, and EXP248 should be
grounded by connecting a #14 or #12 AWG
conductor between the grounding screw (on the
rear panel of the DSLAM, refer to Figure 1.5)
and the earth ground or main grounding bar.
The resistance between the chassis and the
grounding bar should be less than 25 Ohm.
Figure 1.5A EXP212, EXP224 Grounding Screw
on the Rear Panel
Figure 1.5B EXP248 Grounding Screw and AC
Supply Socket (Option) on the Rear Panel
1.2.4 CONNECTING THE FAN CABLE
(EXP248 ONLY)
There are two FAN ports on the front panel of
EXP248. One is on the FAN card; the other is
beside the housekeeping (HK) port. To make
the fans work, you must use an RJ45-to-RJ45
connector cable to connect the two FAN ports.